Isotopologue

In chemistry, isotopologues are molecules that differ only in their isotopic composition.[1] They have the same chemical formula and bonding arrangement of atoms, but at least one atom has a different number of neutrons than the parent.

An example is water, whose hydrogen-related isotopologues are: "light water" (HOH or H2O), "semi-heavy water" with the deuterium isotope in equal proportion to protium (HDO or 1H2HO), "heavy water" with two deuterium isotopes of hydrogen per molecule (D2O or 2H2O), and "super-heavy water" or tritiated water (T2O or 3H2O, as well as HTO [1H3HO] and DTO [2H3HO], where some or all of the hydrogen atoms are replaced with the radioactive tritium isotope). Oxygen-related isotopologues of water include the commonly available form of heavy-oxygen water (H218O) and the more difficult to separate version with the 17O isotope. Both elements may be replaced by isotopes, for example in the doubly labeled water isotopologue D218O. All taken together, there are 9 different stable water isotopologues,[2] and 9 radioactive isotopologues involving tritium,[3] for a total of 18. However only certain ratios are possible in mixture, due to prevalent hydrogen swapping.

The atom(s) of the different isotope may be anywhere in a molecule, so the difference is in the net chemical formula. If a compound has several atoms of the same element, any one of them could be the altered one, and it would still be the same isotopologue. When considering the different locations of the same isotopically modified element, the term isotopomer, first proposed by Seeman and Paine in 1992, is used.[4][5] Isotopomerism is analogous to constitutional isomerism of different elements in a structure. Depending on the formula and the symmetry of the structure, there might be several isotopomers of one isotopologue. For example, ethanol has the molecular formula C2H6O. Mono-deuterated ethanol, C2H5DO, is an isotopologue of it. The structural formulas CH3−CH2−O−D and CH2D−CH2−O−H are two isotopomers of that isotopologue.

Singly substituted isotopologues

Analytical chemistry applications

Singly substituted isotopologues may be used for nuclear magnetic resonance experiments, where deuterated solvents such as deuterated chloroform (CDCl3) do not interfere with the solutes' 1H signals, and in investigations of the kinetic isotope effect.

Geochemical applications

In the field of stable isotope geochemistry, isotopologues of simple molecules containing rare heavy isotopes of carbon, oxygen, hydrogen, nitrogen, and sulfur are used to trace equilibrium and kinetic processes in natural environments and in Earth's past.

Doubly substituted isotopologues

Measurement of the abundance of clumped isotopes (doubly substituted isotopologues) of gases has been used in the field of stable isotope geochemistry to trace equilibrium and kinetic processes in the environment inaccessible by analysis of singly substituted isotopologues alone.

Currently measured doubly substituted isotopologues include:

Analytical requirements

Because of the relative rarity of the heavy isotopes of C, H, and O, isotope-ratio mass spectrometry (IRMS) of doubly substituted species requires larger volumes of sample gas and longer analysis times than traditional stable isotope measurements, thereby requiring extremely stable instrumentation. In addition, the doubly-substituted isotopologues are often subject to isobaric interferences, as in the methane system where 13CH5+ and 12CH3D+ ions interfere with measurement of the 12CH2D2+ and 13CH3D+ species at mass 18. A measurement of such species requires either very high mass resolving power to separate one isobar from another,[13] or modeling of the contributions of the interfering species to the abundance of the species of interest. These analytical challenges are significant: The first publication precisely measuring doubly substituted isotopologues did not appear until 2004, though singly substituted isotopologues had been measured for decades previously.[14]

As an alternative to more conventional gas source IRMS instruments, tunable diode laser absorption spectroscopy has also emerged as a method to measure doubly substituted species free from isobaric interferences, and has been applied to the methane isotopologue 13CH3D.

Equilibrium fractionation

When a light isotope is replaced with a heavy isotope (e.g., 13C for 12C), the bond between the two atoms will vibrate more slowly, thereby lowering the zero-point energy of the bond and acting to stabilize the molecule.[15] An isotopologue with a doubly substituted bond is therefore slightly more thermodynamically stable, which will tend to produce a higher abundance of the doubly substituted (or “clumped”) species than predicted by the statistical abundance of each heavy isotope (known as a stochastic distribution of isotopes). This effect increases in magnitude with decreasing temperature, so the abundance of the clumped species is related to the temperature at which the gas was formed or equilibrated.[16] By measuring the abundance of the clumped species in standard gases formed in equilibrium at known temperatures, the thermometer can be calibrated and applied to samples with unknown abundances.

Kinetic fractionation

The abundances of multiply substituted isotopologues can also be affected by kinetic processes. As for singly substituted isotopologues, departures from thermodynamic equilibrium in a doubly-substituted species can implicate the presence of a particular reaction taking place. Photochemistry occurring in the atmosphere has been shown to alter the abundance of 18O2 from equilibrium, as has photosynthesis.[17] Measurements of 13CH3D and 12CH2D2 can identify microbial processing of methane and have been used to demonstrate the significance of quantum tunneling in the formation of methane, as well as mixing and equilibration of multiple methane reservoirs. Variations in the relative abundances of the two N2O isotopologues 14N15N18O and 15N14N18O can distinguish whether N2O has been produced by bacterial denitrification or by bacterial nitrification.

Multiple substituted isotopologues

Biochemical applications

Multiple substituted isotopologues may be used for nuclear magnetic resonance or mass spectrometry experiments, where isotopologues are used to elucidate metabolic pathways in a qualitative (detect new pathways) or quantitative (detect quantitative share of a pathway) approach. A popular example in biochemistry is the use of uniform labelled glucose (U-13C glucose), which is metabolized by the organism under investigation (e. g. bacterium, plant, or animal) and whose signatures can later be detected in newly formed amino acid or metabolically cycled products.

Mass spectrometry applications

Resulting from either naturally occurring isotopes or artificial isotopic labeling, isotopologues can be used in various mass spectrometry applications.

Applications of natural isotopologues

The relative mass spectral intensity of natural isotopologues, calculable from the fractional abundances of the constituent elements, is exploited by mass spectrometry practitioners in quantitative analysis and unknown compound identification:

  1. To identify the more likely molecular formulas for an unknown compound based on the matching between the observed isotope abundance pattern in an experiment and the expected isotope abundance patterns for given molecular formulas.[18][19][20]
  2. To expand the linear dynamic response range of the mass spectrometer by following multiple isotopologues, with an isotopologue of lower abundance still generating linear response even while the isotopologues of higher abundance giving saturated signals.[21][22]

Applications of isotope labeling

A compound tagged by replacing specific atoms with the corresponding isotopes can facilitate the following mass spectrometry methods:

  1. Metabolic flux analysis (MFA)[23]
  2. Stable isotopically labeled internal standards for quantitative analysis[24]

See also

References

  1. IUPAC, Compendium of Chemical Terminology, 2nd ed. (the "Gold Book") (1997). Online corrected version: (1994) "Isotopologue". doi:10.1351/goldbook.I03351
  2. The nine stable isotopologues are H216O, H16OD, D216O, H217O, H17OD, D217O, H218O, H18OD, D218O
  3. The nine tritiated isotopologues are H16OT, D16OT, T216O, H17OT, D17OT, T217O, H18OT, D18OT, T218O
  4. Seeman, Jeffrey I.; Secor, Henry V.; Disselkamp, R.; Bernstein, E. R. (1992). "Conformational analysis through selective isotopic substitution: supersonic jet spectroscopic determination of the minimum energy conformation of o-xylene". Journal of the Chemical Society, Chemical Communications (9): 713. doi:10.1039/C39920000713.
  5. Seeman, Jeffrey I.; Paine, III, John B. (December 7, 1992). "Letter to the Editor: 'Isotopomers, Isotopologs'". Chemical & Engineering News. American Chemical Society. 70 (2). doi:10.1021/cen-v070n049.p002. Retrieved 28 August 2020.
  6. Ghosh, Prosenjit, et al. "13C–18O bonds in carbonate minerals: A new kind of paleothermometer". Geochimica et Cosmochimica Acta 70.6 (2006): 1439–1456.
  7. Young E. D., Kohl I. E., Sherwood Lollar B., Etiope G., Rumble D. III, Li S., Haghnegahdar M. A., Schauble E. A., McCain K. A., Foustoukos D. I., Sutclife C., Warr O., Ballentine C. J., Onstott T. C., Hosgormez H., Neubeck A., Marques J. M., Pérez-Rodríguez I., Rowe A. R., LaRowe D. E., Magnabosco C., Yeung L. Y., Ash J. L., and Bryndzia L. T. (2017) "The relative abundances of resolved 12CH2D2 and 13CH3D and mechanisms controlling isotopic bond ordering in abiotic and biotic methane gas". Geochimica et Cosmochimica Acta 203, 235–264.
  8. Ono, Shuhei (2014). "Measurement of a Doubly Substituted Methane Isotopologue,13CH3D, by Tunable Infrared Laser Direct Absorption Spectroscopy". Analytical Chemistry. 86 (13): 6487–6494. doi:10.1021/ac5010579. hdl:1721.1/98875. PMID 24895840.
  9. Stolper, D. A.; Sessions, A. L.; Ferreira, A. A.; Neto, E. V. Santos; Schimmelmann, A.; Shusta, S. S.; Valentine, D. L.; Eiler, J. M. (2014). "Combined 13C–D and D–D clumping in methane: methods and preliminary results". Geochim. Cosmochim. Acta. 126: 169–191. Bibcode:2014GeCoA.126..169S. doi:10.1016/j.gca.2013.10.045.
  10. Yeung, L. Y.; Young, E. D.; Schauble, E. A. (2012). "Measurements of 18O18O and 17O18O in the atmosphere and the role of isotope-exchange reactions". Journal of Geophysical Research. 117 (D18): D18306. Bibcode:2012JGRD..11718306Y. doi:10.1029/2012JD017992.
  11. Young, E. D.; Rumble, D. III; Freedman, P.; Mills, M. (2016). "A large-radius high-mass-resolution multiple-collector isotope ratio mass spectrometer for analysis of rare isotopologues of O2, N2, and CH4 and other gases". International Journal of Mass Spectrometry. 401: 1–10. Bibcode:2016IJMSp.401....1Y. doi:10.1016/j.ijms.2016.01.006.
  12. Magyar, P. M., Orphan, V. J., and Eiler, J. M. (2016) Measurement of rare isotopologues of nitrous oxide by high-resolution multi-collector mass spectrometry. Rapid Commun. Mass Spectrom., 30: 1923–1940.
  13. Eiler, John M.; et al. (2013). "A high-resolution gas-source isotope ratio mass spectrometer". International Journal of Mass Spectrometry. 335: 45–56. Bibcode:2013IJMSp.335...45E. doi:10.1016/j.ijms.2012.10.014.
  14. Eiler, J. M.; Schauble, E. (2004). "18O13C16O in Earth's atmosphere". Geochimica et Cosmochimica Acta. 68 (23): 4767–4777. Bibcode:2004GeCoA..68.4767E. doi:10.1016/j.gca.2004.05.035.
  15. Urey, H. C., 1947. The thermodynamic properties of isotopic substances. J. Chem. Soc. London 1947, 561–581.
  16. Wang, Z.; Schauble, E. A.; Eiler, J. M. (2004). "Equilibrium thermodynamics of multiply substituted isotopologues of molecular gases". Geochim. Cosmochim. Acta. 68 (23): 4779–4797. Bibcode:2004GeCoA..68.4779W. doi:10.1016/j.gca.2004.05.039.
  17. Yeung, L. Y.; Ash, J. L.; Young, E. D. (2015). "Biological signatures in clumped isotopes of O2". Science. 348 (6233): 431–434. Bibcode:2015Sci...348..431Y. doi:10.1126/science.aaa6284. PMID 25908819.
  18. Böcker, S. (2009). "SIRIUS: Decomposing isotope patterns for metabolite identification". Bioinformatics. 25 (2): 218–224. doi:10.1093/bioinformatics/btn603. PMC 2639009. PMID 19015140.
  19. Wang, Yongdong (2010). "The Concept of Spectral Accuracy for MS". Anal. Chem. 82 (17): 7055–7062. doi:10.1021/ac100888b. PMID 20684651.
  20. Bluck, Les. "The Role of Naturally Occurring Stable Isotopes in Mass Spectrometry, Part I: The Theory". Spectroscopy. 23 (10): 36. PMID 23772100.
  21. Liu, Hanghui (2011). "Expanding the linear dynamic range for multiple reaction monitoring in quantitative liquid chromatography–tandem mass spectrometry utilizing natural isotopologue transitions". Talanta. 87: 307–310. doi:10.1016/j.talanta.2011.09.063.
  22. Bach, Thanh (2022). "Importance of Utilizing Natural Isotopologue Transitions in Expanding the Linear Dynamic Range of LC-MS/MS Assay for Small-Molecule Pharmacokinetic Sample Analysis – A mini-review". Journal of Pharmaceutical Sciences. 111 (5): 1245–1249. doi:10.1016/j.xphs.2021.12.012. PMC 9018470. PMID 34919967.
  23. Wang, Yujue (2020). "Metabolic Flux Analysis-Linking Isotope Labeling and Metabolic Fluxes". Metabolites. 10 (11): 447. doi:10.3390/metabo10110447. PMC 7694648. PMID 33172051.
  24. Stokvis, Ellen (2005). "Stable isotopically labeled internal standards in quantitative bioanalysis using liquid chromatography/mass spectrometry: necessity or not?". Rapid Communications in Mass Spectrometry. 19 (3): 401–407. doi:10.1002/rcm.1790. PMID 15645520.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.