The MK II Method is one of the software sizing methods in functional point group of measurements. This is a method for analysis and measurement of information processing applications based on end user functional view of the system. The MK II Method (ISO/IEC 20968 Software engineering—Mk II Function Point Analysis—Counting Practices Manual[1]) is one of five currently recognized ISO standards for Functionally sizing software.
Introduction
The MK II Method was defined by Charles Symons in book[2] published in 1991. UK Software Metrics Association[3] is now responsible for the method and its continuing development. The functional user requirements of the software are identified and each one is categorized into one of there types: inputs, exits and objects. In order to determine functional size of system these functional requirements are counted.
MkII FPA counting rules
MkII counting procedure contains several steps described below.
Determine the ViewPoint, Purpose and Type of the Count
Define the Boundary of the Count
Boundary of system represents logical line that separates users from a system. It is used to determine logical transactions such as inputs and exits that crosses boundary during the interaction between user and system.
Identify the Logical Transactions
Each transaction is counted once even though it may be executed from more than one point in the application.
Identify and Categorise Data Entity Types
Data entity types are logical data structures that contains information meaningful to the user. In MarkII method there is only one type of data entity types - Objects. Objects must be correctly identified so they can be counted.
Count the Input Data Element Types, the Data entity Types Referenced, and the Output Data Element Types
This can be done by a simple spreadsheet and needs to be added up and applied a formula to find the exact MKII FPA value
Count the Functional Size
Once the transactions and objects in the system are identified, they can be counted in order to find functional size of the system. Functional size of the system is represented as weighted counts of input/exit transactions and objects within the boundary of the system. Size can be expressed as following:
Size = Wi*ΣNi+ We*ΣNe + Wo*ΣNo
In the equation ΣNi, ΣNe and ΣNo are total numbers of unique inputs, exits and objects within the system. Currently recommended values for weighting coefficients are Wi = 0.58, We = 1.66, and Wo = 0.26.
References
- "Iso/Iec 20968:2002".
- Software Sizing and Estimating: Mk II Fpa (Function Point Analysis)
- "Home". uksma.co.uk.