Deluge gun

A deluge gun, fire monitor, master stream or deck gun is an aimable controllable high-capacity water jet used for manual firefighting or automatic fire protection systems. Deluge guns are often designed to accommodate foam which has been injected in the upstream piping.

A deck gun in the foreground puts water through a window while a ladder-mounted master stream in the background directs water through the collapsed roof.
Fixed fire monitor at a plastic manufacturing factory

Installation

Deluge guns are often fitted to fire boats, tug boats, and atop large fire trucks for use in manual firefighting, where they can be aimed and operated by one firefighter and are used to deliver water or foam from outside the immediate area of the fire. Deluge guns are sometimes installed in fixed fire protection systems to protect high hazards, such as aviation hangars and helicopter landing pads. Similarly, facilities with highly flammable material such as oil refineries may have permanently-installed deluge guns. Most apparatus-mounted deluge guns can be directed by a single firefighter, compared to a standard fire hose which normally requires several. Deluge guns can be automatically positioned for fixed systems, or may have portable designs. The latter option enables a firefighter to set up the gun to apply water to a blaze, before leaving it in place to attend to other tasks.

Capacity

A deluge gun can discharge 7,500 litres (2,000 US gal) per minute or more. A master stream is a fire service term for a water stream of 1,250 litres (330 US gal) per minute or greater. It is delivered by a master stream device, such as a deck gun, deluge gun, or fire monitor. Master streams are often found at the end of aerial ladders, tele-squirt nozzles, or monitor nozzles. The high pressure that they require renders them unsuitable for handline use.

Risks

A master stream brings with it many risks when used in an urban setting. A master stream should never be fired into an occupied building, as the force could knock down a supporting wall and crush victims. Also, the steam from the high volume of water delivered could cause a blowout or displace oxygen from an enclosed area, creating a risk of asphyxiation.

See also

References

  • Hall, Richard (1998). Adams, Barbara (ed.). Essentials of Fire Fighting (4th ed.). Stillwater, OK: Fire Protection Publication. ISBN 0-87939-149-9.
  • US Patent for improved mobile fire apparatus
  • ABS Rules for Steel Vessels 2007 5C.9.11/3 Specific Vessel Types- Chemical Carriers, Fire Protection and Fire Extinction
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.