X-ray diffraction computed tomography

X-ray diffraction computed tomography is an experimental technique that combines X-ray diffraction with the computed tomography data acquisition approach. X-ray diffraction (XRD) computed tomography (CT) was first introduced in 1987 by Harding et al.[1] using a laboratory diffractometer and a monochromatic X-ray pencil beam. The first implementation of the technique at synchrotron facilities was performed in 1998 by Kleuker et al.[2]

X-ray diffraction computed tomography can be divided into two main categories depending on how the XRD data are being treated, specifically the XRD data can be treated either as powder diffraction or single crystal diffraction data and this depends on the sample properties. If the sample contains small and randomly oriented crystals, then it generates smooth powder diffraction "rings" when using a 2D area detector. If the sample contains large crystals, then it generates "spotty" 2D diffraction patterns. The latter can be performed using also a letterbox, cone and parallel X-ray beam and yields 2D or 3D images corresponding to maps of the crystallites or "grains" present in the sample and their properties, such as stress or strain.[3] There exist several variations of this approach including 3DXRD,[4] X-ray diffraction contrast tomography (DCT)[5] and high energy X-ray diffraction microscopy (HEDM)[6]

X-ray diffraction computed tomography, often abbreviated as XRD-CT, typically refers to the technique invented by Harding et al.[1] which assumes that the acquired data are powder diffraction data. For this reason, it has also been mentioned as powder diffraction computed tomography [7] and diffraction scattering computed tomography (DSCT),[8] however they both refer to the same method.

Data acquisition

XRD-CT employs a monochromatic pencil beam scanning approach and captures the diffraction signal in transmission geometry, producing a diffraction projection dataset. In this setup, the sample moves along an axis perpendicular to the beam's direction. It is illuminated with a monochromatic finely collimated or focused "pencil" X-ray beam. A 2D area detector then records the scattered X-rays, optimizing for best counting statistics and speed. Typically, the translational scan's size surpasses the sample's diameter, ensuring its full coverage at all assessed angles. The size of the translation step is commonly aligned with the X-ray beam's horizontal size. In a perfect scenario for any pencil-beam scanning tomographic method, the measured angles should match the number of translation steps multiplied by π/2, adhering to the Nyquist sampling theorem. However, this number can often be reduced in practice be equal to the number of translation steps without substantially compromising the quality of reconstructed images. The usual angular range spans from 0 to π.

Data reconstruction

In most studies, the predominant data reconstruction approach is the 'reverse analysis' introduced by Bleuet et al.[9] where each sinogram is treated independently yielding a new CT image. Most oftern the filtered back projection reconstruction algorithm [10] is employed to reconstruct the XRD-CT images. The outcome is an image in which every pixel, or more accurately voxel, equates to a local diffraction pattern. The reconstructed data can also be seen as a stack of 2D square images, where each image corresponds to an X-ray scattering angle.

Reconstruction artefacts

XRD-CT makes the following assumptions:

  • The sample is small and there are no significant parallax artefacts in the acquired diffraction data; when this assumption is not valid the reconstructed patterns contain a wide range of artefacts, such as inaccurate peak positions, peak shapes and even arteficial peak splitting
  • The acquired XRD data are powder diffraction-like and do not contain spotty data
  • The sample is not strongly absorbing the X-rays and there are no significant self-absorption problems in the acquired data
  • The chemistry of the sample is not changing significantly during the XRD-CT scan

In practise, one or more of these assumptions are not valid and the data suffer from artefacts. There are strategies to remove or significantly all of these artefacts:

  • Rather than employing the filtered back projection reconstruction algorithm to reconstruct the XRD-CT images, it is possible to use another reconstruction approach, termed "Direct Least Squares Reconstruction" (DLSR) to perform simultaneously peak fitting and tomographic reconstruction which takes into account the geometry of the experimental setup and yields parallax artefact-free reconstructed images.[11] Performing a 0 to 2π XRD-CT scan instead of 0 to π can lead to reconstructed patterns with accurate peak position but not peak shape.
  • Spotty 2D XRD data acquired during the XRD-CT scan lead to streak or line artefacts in the reconstructed XRD-CT data; it is possible to remove or suppress these artefacts by applying filters during the azimuthal integration of the raw 2D diffraction patterns[12]
  • The data can be corrected for self-absorption artefacts using an X-ray absorption-contrast CT scan of the same sample.
  • If the solid-state chemistry of the sample is changing during the XRD-CT scan, then other data acquisition approaches can be employed that can improve the temporal resolution of the method, such as the interlaced approach[13][14]

Data analysis

Analyzing the local diffraction patterns can range from basic single-peak sequential batch fitting to a comprehensive one-step full-profile analysis, known as 'Rietveld-CT' (Wragg et al., 2015 [15]). The latter method stands out for its efficiency over the typical sequential method since it shares global parameters across all local models. Examples of these parameters include zero error and instrumental broadening, which enhance the refinement process's stability. To elaborate, each voxel in the restructured images is made up of a local model (like multi-phase scale factors, lattice parameters, and crystallite sizes) tailored to match the corresponding local diffraction pattern. This implies that only the overarching parameters are consistent across local models. However, the application of Rietveld-CT has been limited to small images, specifically those of 60 × 60 voxels, with the feasibility for larger images hinging on the computer memory available. Most often though full profile analysis of the local diffraction patterns is performed on a pixel-by-pixel or line-by-line basis using conventional XRD data analysis methods, such LeBail, Pawley and Rietveld. All these methods employ fitting based on the restructured diffraction patterns. Another approach which is also computational expensive is the DLSR which performs the tomographic data reconstruction and peak fitting in a single step.[11] Regardless of the chosen analytical method, the final output comprises images filled with localized physico-chemical information. Each physico-chemical image corresponds to the refined parameters present in the local models, which might include maps that correspond to scale factors, lattice parameters, and crystallite sizes.

See also

References

  1. Harding, G.; Kosanetzky, J.; Neitzel, U. (July 1987). "X-ray diffraction computed tomography: X-ray diffraction computed tomography". Medical Physics. 14 (4): 515–525. doi:10.1118/1.596063. PMID 3626990.
  2. Kleuker, U; Suortti, P; Weyrich, W; Spanne, P (1998-10-01). "Feasibility study of x-ray diffraction computed tomography for medical imaging". Physics in Medicine and Biology. 43 (10): 2911–2923. Bibcode:1998PMB....43.2911K. doi:10.1088/0031-9155/43/10/017. ISSN 0031-9155. PMID 9814526. S2CID 250820853.
  3. Hayashi, Yujiro; Setoyama, Daigo; Hirose, Yoshiharu; Yoshida, Tomoyuki; Kimura, Hidehiko (2019-12-20). "Intragranular three-dimensional stress tensor fields in plastically deformed polycrystals". Science. 366 (6472): 1492–1496. Bibcode:2019Sci...366.1492H. doi:10.1126/science.aax9167. ISSN 0036-8075. PMID 31857480. S2CID 209424420.
  4. Poulsen, Henning (2004). Three-Dimensional X-Ray Diffraction Microscopy. Springer Tracts in Modern Physics. Vol. 205. Berlin, Heidelberg: Springer Berlin Heidelberg. doi:10.1007/b97884. ISBN 978-3-540-22330-6.
  5. Ludwig, Wolfgang; Schmidt, Søeren; Lauridsen, Erik Mejdal; Poulsen, Henning Friis (2008-04-01). "X-ray diffraction contrast tomography: a novel technique for three-dimensional grain mapping of polycrystals. I. Direct beam case". Journal of Applied Crystallography. 41 (2): 302–309. doi:10.1107/S0021889808001684. ISSN 0021-8898.
  6. Suter, R. M.; Hennessy, D.; Xiao, C.; Lienert, U. (2006-12-01). "Forward modeling method for microstructure reconstruction using x-ray diffraction microscopy: Single-crystal verification". Review of Scientific Instruments. 77 (12): 123905–123905–12. Bibcode:2006RScI...77l3905S. doi:10.1063/1.2400017. ISSN 0034-6748.
  7. Kochetov, Vladislav; Mühlbauer, Martin J; Schökel, Alexander; Fischer, Torben; Müller, Timo; Hofmann, Michael; Staron, Peter; Lienert, Ulrich; Petry, Winfried; Senyshyn, Anatoliy (2021-03-10). "Powder diffraction computed tomography: a combined synchrotron and neutron study". Journal of Physics: Condensed Matter. 33 (10): 105901. Bibcode:2021JPCM...33j5901K. doi:10.1088/1361-648X/abcdb0. ISSN 0953-8984. PMID 33237884. S2CID 227176156.
  8. Birkbak, M. E.; Leemreize, H.; Frølich, S.; Stock, S. R.; Birkedal, H. (2015). "Diffraction scattering computed tomography: a window into the structures of complex nanomaterials". Nanoscale. 7 (44): 18402–18410. Bibcode:2015Nanos...718402B. doi:10.1039/C5NR04385A. ISSN 2040-3364. PMC 4727839. PMID 26505175.
  9. Bleuet, Pierre; Welcomme, Eléonore; Dooryhée, Eric; Susini, Jean; Hodeau, Jean-Louis; Walter, Philippe (June 2008). "Probing the structure of heterogeneous diluted materials by diffraction tomography". Nature Materials. 7 (6): 468–472. Bibcode:2008NatMa...7..468B. doi:10.1038/nmat2168. ISSN 1476-4660. PMID 18425135.
  10. Bracewell, R. N.; Riddle, A. C. (November 1967). "Inversion of Fan-Beam Scans in Radio Astronomy". The Astrophysical Journal. 150: 427. Bibcode:1967ApJ...150..427B. doi:10.1086/149346. ISSN 0004-637X.
  11. Vamvakeros, A.; Coelho, A. A.; Matras, D.; Dong, H.; Odarchenko, Y.; Price, S. W. T.; Butler, K. T.; Gutowski, O.; Dippel, A.-C.; Zimmermann, M.; Martens, I.; Drnec, J.; Beale, A. M.; Jacques, S. D. M. (2020-12-01). "DLSR: a solution to the parallax artefact in X-ray diffraction computed tomography data". Journal of Applied Crystallography. 53 (6): 1531–1541. doi:10.1107/S1600576720013576. ISSN 1600-5767. S2CID 229431294.
  12. Vamvakeros, A.; Jacques, S. D. M.; Di Michiel, M.; Middelkoop, V.; Egan, C. K.; Cernik, R. J.; Beale, A. M. (2015-12-01). "Removing multiple outliers and single-crystal artefacts from X-ray diffraction computed tomography data". Journal of Applied Crystallography. 48 (6): 1943–1955. doi:10.1107/S1600576715020701. ISSN 1600-5767.
  13. Kaestner, Anders P.; Munch, Beat; Trtik, Pavel (December 2011). "Spatiotemporal computed tomography of dynamic processes". Optical Engineering. 50 (12): 123201–123201–9. Bibcode:2011OptEn..50l3201K. doi:10.1117/1.3660298. ISSN 0091-3286. S2CID 121903995.
  14. Vamvakeros, A.; Jacques, S. D. M.; Di Michiel, M.; Senecal, P.; Middelkoop, V.; Cernik, R. J.; Beale, A. M. (2016-04-01). "Interlaced X-ray diffraction computed tomography". Journal of Applied Crystallography. 49 (2): 485–496. doi:10.1107/S160057671600131X. ISSN 1600-5767. PMC 4815873. PMID 27047305.
  15. Wragg, D. S.; O'Brien, M. G.; Di Michiel, M.; Lønstad-Bleken, F. (2015-12-01). "Rietveld analysis of computed tomography and its application to methanol to olefin reactor beds". Journal of Applied Crystallography. 48 (6): 1719–1728. doi:10.1107/S1600576715017288. hdl:10852/47665. ISSN 1600-5767.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.