Enhanced Fujita scale
The Enhanced Fujita scale (abbreviated as EF-Scale) rates tornado intensity based on the severity of the damage they cause. It is used in some countries, including the United States, Canada, China, and Mongolia.
EFU | Unknown | No surveyable damage |
---|---|---|
EF0 | 65–85 mph | Light damage |
EF1 | 86–110 mph | Moderate damage |
EF2 | 111–135 mph | Considerable damage |
EF3 | 136–165 mph | Severe damage |
EF4 | 166–200 mph | Devastating damage |
EF5 | >200 mph | Incredible damage |
The Enhanced Fujita scale replaced the decommissioned Fujita scale that was introduced in 1971 by Ted Fujita. Operational use began in the United States on February 1, 2007, followed by Canada on April 1, 2013.[1][2][3] It has also been proposed for use in France.[4] The scale has the same basic design as the original Fujita scale—six intensity categories from zero to five, representing increasing degrees of damage. It was revised to reflect better examinations of tornado damage surveys, in order to align wind speeds more closely with associated storm damage. Better standardizing and elucidating what was previously subjective and ambiguous, it also adds more types of structures and vegetation, expands degrees of damage, and better accounts for variables such as differences in construction quality. An "EF-Unknown" (EFU) category was later added for tornadoes that cannot be rated due to a lack of damage evidence.[5]
The newer scale was publicly unveiled by the National Weather Service at a conference of the American Meteorological Society in Atlanta on February 2, 2006. It was developed from 2000 to 2004 by the Fujita Scale Enhancement Project of the Wind Science and Engineering Research Center at Texas Tech University, which brought together dozens of expert meteorologists and civil engineers in addition to its own resources.[6]
As with the Fujita scale, the Enhanced Fujita scale remains a damage scale and only a proxy for actual wind speeds. While the wind speeds associated with the damage listed have not undergone empirical analysis (such as detailed physical or any numerical modeling) owing to excessive cost, the wind speeds were obtained through a process of expert elicitation based on various engineering studies since the 1970s as well as from the field experience of meteorologists and engineers. In addition to damage to structures and vegetation, radar data, photogrammetry, and cycloidal marks (ground swirl patterns) may be utilized when available.
The scale was used for the first time in the United States a year after its public announcement when parts of central Florida were struck by multiple tornadoes, the strongest of which were rated at EF3 on the new scale. It was used for the first time in Canada shortly after its implementation there when a tornado developed near the town of Shelburne, Ontario, on April 18, 2013, causing up to EF1 damage.[7]
Parameters
The seven categories for the EF scale are listed below, in order of increasing intensity. Although the wind speeds and photographic damage examples have been updated, the damage descriptions given are based on those from the Fujita scale, which are more or less still accurate. However, for the actual EF scale in practice, damage indicators (the type of structure which has been damaged) are predominantly used in determining the tornado intensity.[8]
Scale | Wind speed estimate[9] | Frequency[10] | Potential damage | Example of damage | |
---|---|---|---|---|---|
mph | km/h | ||||
EFU | N/A | N/A | 3.11% | No surveyable damage.Intensity cannot be determined due to a lack of information. This rating applies to tornadoes that traverse areas with no damage indicators, cause damage in an area that cannot be accessed by a survey, or cause damage which cannot be differentiated from that of another tornado.[5] | N/A |
EF0 | 65–85 | 105–137 | 52.82% | Minor damage.Small trees are blown down and bushes are uprooted. Shingles are ripped off roofs, windows in cars and buildings are blown out, medium to large branches snapped off of large trees, sheds are majorly damaged, and loose small items are tossed and blown away (i.e. lawn chairs, plastic tables, sports equipment, mattresses). Barns are damaged.[11] | |
EF1 | 86–110 | 138–177 | 32.98% | Moderate damage.Roofs stripped from shingles or planting. Small areas of roof may be blown off house. Doors and garage doors blown in, siding ripped off houses, mobile homes flipped or rolled onto their sides, small trees uprooted, large trees snapped or blown down, telephone poles snapped, outhouses and sheds blown away. Cars occasionally flipped or blown over, and moderate roof and side damage to barns. Corn stalks slightly bent and stripped of leaves. | |
EF2 | 111–135 | 178–217 | 8.41% | Considerable damage.Whole roofs ripped off frame houses, interiors of frame homes damaged, small and medium trees uprooted. Weak structures such as barns and mobile homes are completely destroyed. | |
EF3 | 136–165 | 218–266 | 2.18% | Severe damage.Roofs and numerous outside walls blown away from frame homes, all trees in its path uprooted or lofted. Two-story homes have their second floor destroyed, high-rises have many windows blown out, radio towers blown down, metal buildings (i.e. factories, power plants, and construction sites) are heavily damaged, sometimes completely destroyed. Large vehicles such as tractors, buses, and forklifts are blown from their original positions. | |
EF4 | 166–200 | 267–322 | 0.46% | Devastating damage.Trees partially debarked, cars are mangled and thrown in the air, frame homes are completely destroyed and some may be swept away, moving trains blown off railroad tracks, and barns are leveled. | |
EF5 | >200 | >322 | 0.05% | Incredible damage.Cars are mangled and thrown hundreds, possibly thousands of yards away. Frame homes, brick homes, and small businesses, are swept away, trees debarked, corn stalks flattened or ripped out of the ground, skyscrapers sustain major structural damage, grass ripped out of the ground. Wood and any small solid material become dangerous projectiles. |
Damage indicators and degrees of damage
The EF scale currently has 28 damage indicators (DI), or types of structures and vegetation, each with a varying number of degrees of damage (DoD). Each structure has a maximum DoD value, which is given by total destruction. Lesser damage to a structure will yield lower DoD values.[12] The links in the right column of the following table describe the degrees of damage for the damage indicators listed in each row.
DI No. | Damage indicator (DI) | Maximum degrees of damage |
---|---|---|
1 | Small barns or farm outbuildings (SBO) | 8 |
2 | One- or two-family residences (FR12) | 10 |
3 | Manufactured home – single wide (MHSW) | 9 |
4 | Manufactured home – double wide (MHDW) | 12 |
5 | Apartments, condos, townhouses [three stories or less] (ACT) | 6 |
6 | Motel (M) | 10 |
7 | Masonry apartment or motel building (MAM) | 7 |
8 | Small retail building [fast-food restaurants] (SRB) | 8 |
9 | Small professional building [doctor's office, branch banks] (SPB) | 9 |
10 | Strip mall (SM) | 9 |
11 | Large shopping mall (LSM) | 9 |
12 | Large, isolated retail building [K-Mart, Wal-Mart] (LIRB) | 7 |
13 | Automobile showroom (ASR) | 8 |
14 | Automobile service building (ASB) | 8 |
15 | Elementary school [single-story; interior or exterior hallways] (ES) | 10 |
16 | Junior or senior high school (JHSH) | 11 |
17 | Low-rise building [1–4 stories] (LRB) | 7 |
18 | Mid-rise building [5–20 stories] (MRB) | 10 |
19 | High-rise building [more than 20 stories] (HRB) | 10 |
20 | Institutional building [hospital, government or university building] (IB) | 11 |
21 | Metal building system (MBS) | 8 |
22 | Service station canopy (SSC) | 6 |
23 | Warehouse building [tilt-up walls or heavy-timber construction] (WHB) | 7 |
24 | Electrical transmission lines (ETL) | 6 |
25 | Free-standing towers (FST) | 3 |
26 | Free-standing light poles, luminary poles, flag poles (FSP) | 3 |
27 | Trees: hardwood (TH) | 5 |
28 | Trees: softwood (TS) | 5 |
Differences from the Fujita scale
The new scale takes into account the quality of construction and standardizes different kinds of structures. The wind speeds on the original scale were deemed by meteorologists and engineers as being too high, and engineering studies indicated that slower winds than initially estimated cause the respective degrees of damage.[13] The old scale lists an F5 tornado as wind speeds of 261–318 mph (420–512 km/h), while the new scale lists an EF5 as a tornado with winds above 200 mph (322 km/h), found to be sufficient to cause the damage previously ascribed to the F5 range of wind speeds. None of the tornadoes in the United States recorded before February 1, 2007, will be re-categorized.
Essentially, there is no functional difference in how tornadoes are rated. The old ratings and new ratings are smoothly connected with a linear formula. The only differences are adjusted wind speeds, measurements of which were not used in previous ratings, and refined damage descriptions; this is to standardize ratings and to make it easier to rate tornadoes which strike few structures. Twenty-eight Damage Indicators (DI), with descriptions such as "double-wide mobile home" or "strip mall", are used along with Degrees of Damage (DoD) to determine wind estimates. Different structures, depending on their building materials and ability to survive high winds, have their own DIs and DoDs. Damage descriptors and wind speeds will also be readily updated as new information is learned.[12] Some differences do exist between the two scales in the ratings assigned to damage. An EF5 rating on the new scale requires a higher standard of construction in houses than does an F5 rating on the old scale. So, the complete destruction and sweeping away of a typical American frame home, which would likely be rated F5 on the Fujita scale, would be rated EF4 or lower on the Enhanced Fujita scale.[14]
Since the new system still uses actual tornado damage and similar degrees of damage for each category to estimate the storm's wind speed, the National Weather Service states that the new scale will likely not lead to an increase in the number of tornadoes classified as EF5. Additionally, the upper bound of the wind speed range for EF5 is open—in other words, there is no maximum wind speed designated.[8]
Rating classifications
EF0 | EF1 | EF2 | EF3 | EF4 | EF5 |
---|---|---|---|---|---|
Weak | Strong | Violent | |||
Significant | |||||
Intense |
For purposes such as tornado climatology studies, Enhanced Fujita scale ratings may be grouped into classes.[15][16][17] Classifications are also used by NOAA's Storm Prediction Center to determine whether the tornado was "significant". This same classification is also used by the National Weather Service.
The table shows other variations of the tornado rating classifications based on certain areas.
See also
- Beaufort scale
- International Fujita scale
- Saffir–Simpson hurricane wind scale
- Severe weather terminology (United States)
- TORRO scale
- Tornado intensity and damage
- Wind engineering
- Lists of tornadoes and tornado outbreaks
- List of F4 and EF4 tornadoes
- List of F5 and EF5 tornadoes
References
- NOAA: Fujita Tornado Damage Scale
- Tornado Damage Scales: Fujita Scale and Enhanced Fujita Scale
- "Enhanced Fujita Scale". Environment Canada. May 10, 2013.
- Mahieu, Pierre; Wesolek, Emmanuel. "Tornado Rating in Europe with the EF-scale" (PDF). Keraunos. Retrieved January 4, 2019.
- Murphy, John D. (July 9, 2018). "National Weather Service Instruction 10-1605" (PDF). National Weather Service. pp. A–74–75. Retrieved November 29, 2019.
- "Enhanced Fujita Scale - Tornado Damage Scale". factsjustforkids.com. Retrieved June 14, 2019.
- "Tornado to Be 1st Assessed by New Scale". The Washington Post. Associated Press. February 2, 2007. Retrieved July 11, 2009.
- "The Enhanced Fujita Scale (EF Scale)". Storm Prediction Center. February 2, 2007. Retrieved June 21, 2009.
- "Enhanced F Scale for Tornado Damage". Storm Prediction Center. Retrieved June 21, 2009.
- "Storm Prediction Center WCM Data". Storm Prediction Center. Retrieved September 15, 2021.
- "Garrett's Blog: Mobile Home Tornado Risk". 5newsonline.com. February 28, 2013. Retrieved September 30, 2020.
- McDonald, James; Kishor C. Mehta (October 10, 2006). A recommendation for an Enhanced Fujita scale (EF-Scale) (PDF). Lubbock, Texas: Wind Science and Engineering Research Center, Texas Tech University. Retrieved May 21, 2013.
- Wind Science and Engineering Center. (2006). A recommendation for an enhanced Fujita scale (EF-scale). Retrieved from National Weather Service Storm Prediction Center website https://www.spc.noaa.gov
- Doswell, Charles A.; Brooks, Harold E.; Dotzek, Nikolai (July 2009). "On the Implementation of the Enhanced Fujita Scale in the USA". Atmospheric Research. 93 (1–3): 556–557. Bibcode:2009AtmRe..93..554D. doi:10.1016/j.atmosres.2008.11.003. Retrieved January 20, 2020.
- Grazulis, Thomas P. (July 1993). Significant Tornadoes 1680–1991. St. Johnsbury, Vermont: The Tornado Project of Environmental Films. ISBN 1-879362-03-1.
- The Fujita Scale of Tornado Intensity Archived December 30, 2011, at the Wayback Machine at tornadoproject.com
- "Severe Thunderstorm Climatology". National Severe Storms Laboratory, National Oceanic and Atmospheric Administration, US Department of Commerce. March 29, 2013. Archived from the original on October 4, 2012. Retrieved May 22, 2013.
- Edwards, Roger; J. G. LaDue; J. T. Ferree; K. Scharfenberg; C. Maier; W. L. Coulbourne (2013). "Tornado Intensity Estimation: Past, Present, and Future". Bull. Amer. Meteor. Soc. 94 (5): 641–53. Bibcode:2013BAMS...94..641E. doi:10.1175/BAMS-D-11-00006.1. S2CID 7842905.
External links
- National Oceanic and Atmospheric Administration
- NOAA National Weather Service Improves Tornado Rating System at NOAA News
- The Enhanced Fujita Scale (EF Scale) at Storm Prediction Center
- EF-Scale Training Archived June 21, 2017, at the Wayback Machine at The Warning Decision Training Branch of National Weather Service (NWS)
- The Enhanced Fujita Tornado Scale at National Climatic Data Center
- The Tornado: An Engineering-Oriented Perspective (NWS SR147)
- A Guide for Conducting Convective Windstorm Surveys (NWS SR146)
- Fujita Scale Enhancement Project (Wind Science and Engineering Research Center at Texas Tech University)
- Symposium on the F-Scale and Severe-Weather Damage Assessment at American Meteorological Society
- A Guide to F-Scale Damage Assessment, MetEd, University Corporation for Atmospheric Research
- Mitigation Assessment Team Report: Midwest Tornadoes of May 3, 1999 (Federal Emergency Management Agency)