Breast cancer is increasing in incidence and is one of the leading types of cancer. Once thought to be mostly a disease of elderly females, there is an increase in the incidence of breast cancer in women during their third and fourth decades of life. With increasing awareness, screening has become more prevalent, which in turn has increased the overall number of positive findings. Additionally, post-treatment monitoring increases with an overall increase in studies and survival rates. In an effort to decrease the morbidity and mortality of breast cancer, technological advances in breast imaging have been developed and are continuing to expand in order to detect breast cancers earlier. Methods of examination for breast cancer include self physical examination, physician physical examination, mammogram, tomography, ultrasound, magnetic resonance imaging (MRI), and positron emission tomography (PET). Another less commonly known and rarely used modality is scintimammography or mammoscintigraphy. Scintimammography is a type of nuclear medicine imaging, which has been considered adjuvant to mammography specifically for cases containing post-surgical changes, indeterminate mammogram findings, post neoadjuvant chemotherapy follow-up, and suspected multifocal disease. MRI of the breast has largely taken the place of scintimammography because it can provide similar information and more such as a high-quality preoperative evaluation. Currently, clinicians have not decided on definite indications for scintimammography, resulting in many studies evaluating its utility.[1][2][3][4]
Studies have attempted to define the importance of scintimammography through comparison of statistical data, including positive predictive values, false negatives, and false positives. The positive predictive value is low for mammograms, given the higher rates of false positives, but when combined with another modality, the positive predictive value will increase, which improves patient care and satisfaction overall.
Breast malignancies have been shown to have increased uptake of radiopharmaceuticals as compared to normal breast parenchyma. The diagnostic evaluation consists of intravenous injection of technetium 99m sestamibi (technetium 99m - DMSA or technetium 99m MDP can also be used, but are less sensitive) with subsequent imaging of the breasts.[5]
Normal distribution of technetium 99m sestamibi (the most commonly used radiopharmaceutical for scintimammography) is the salivary glands, thyroid, myocardium, liver, and gallbladder.
Any uptake of radiopharmaceutical greater than the average breast parenchyma is suspicious for malignancy. If the breast demonstrates mild, homogenous uptake of the radiopharmaceutical, it is considered a normal study. Patchy, widespread uptake likely is not indicative of malignancy. Evaluation of the axilla is important for the interpretation of potential metastasis to axillary lymph nodes in the presence of an ipsilateral focal area of increased uptake suggesting primary malignancy. Axillary folds will demonstrate increased uptake as an artifact and should be considered normal, but can be a pitfall and lateral imaging should be used to identify its superficial location and linear appearance.[6]
Indications for scintimammography are debated given that MRI is currently the more preferred modality for similar indications; however, the most commonly stated reasons scintimammography is performed include equivocal, suspicious, or difficult to interpret mammograms and potential multifocal breast cancer. Additionally, patients with breast implants, axillary lymph node metastasis of an adenocarcinoma of unknown primary origin, and monitoring response to neoadjuvant chemotherapy.[7][8][9][10]
Contraindications for scintimammography are also currently being debated, with most being relative contraindications. Pregnant or lactating women would be at high risk for the fetus and/or infant with exposure to radiation. Scintimammography should not be performed if there is a history of recent surgical intervention including cyst aspiration, fine needle aspiration, core needle biopsy, and excisional biopsy with suggestions of waiting 2 weeks for minor procedures and up to six weeks for major procedures. Appropriate delay in the examination is recommended to minimize the chances of false positives from increased uptake in the post-surgical reactive tissues. Examination during menses should also be avoided, as well as hypersensitivity to technetium 99m.[11]
A standard scintillation camera with a low-energy, high-energy collimator is used. A symmetric 10% energy window is used, centered over the 140 keV photopeak of technetium 99m.[11]
Radiologists, nuclear medicine physicians, nuclear medicine technicians, cyclotron engineers/workers, and scheduling departments are required to set up and execute obtaining a scintimammogram. All members of the team play a vital role in carrying out the task.
No specific preparation is needed for the patient to be ready for a scintimammogram. A nuclear medicine technologist will be an asset to assist in the explanation and execution of the examination. It should be ensured that the patient is capable of lying prone on a hard surface with the arms extended above the head before the procedure is started. The patient should wear a hospital gown and remove all clothing and jewelry.
Quality control should be performed according to the general guidelines by the Society of Nuclear Medicine on the scintillation camera.[11]
Imaging can be obtained in either planar and/or single-photon emission computed tomography. Intravenous injection with an indwelling catheter or butterfly needle of 20-30 mCi of technetium 99m into a vein of the upper extremity should be contralateral to the breast of concern. If there are suspicious bilateral findings, the lower extremity is then injected. Approximately 10 mL of saline flush should follow.
Prone positioning is appropriate with the non-pathological breast compressed against the table to prevent the dependent breast from the artifact of the contralateral breast. The arms are raised over the head with the head turned away from the detector to minimize artifact. The detector is placed against the patient.
The patient should be imaged 5 to 10 minutes after injection. Planar images to be obtained include prone lateral (including the breast, axilla and anterior chest wall), prone posterior oblique, and anterior upright/supine chest (includes bilateral breasts and axillae). If a marker is desired, it should be placed once the breast is in the proper position; otherwise, the abnormality could change in relation to the marker.
The breast tissue is near myocardial tissue, which is an organ that takes up technetium 99m, so post procession count subtraction should be obtained.[11]
The procedure is relatively non-invasive with few adverse effects; however, potential complications could include extravasation of radiopharmaceuticals and allergic reaction to radiopharmaceuticals. Extravasation of technetium 99m has not been shown to cause significant harmful effects to the tissue involved, and usually, surgical intervention would not be necessary. Allergic reactions to radiopharmaceuticals are rare, but if they happen or are at risk of occurring, appropriate steps are given by the American College of Radiology, which includes preparation with corticosteroids and antihistamines as well as emergent medications after the development of symptoms including epinephrine and labetalol.[12]
The main purpose of scintimammography is to increase the positive predictive value of breast cancer detection with imaging in order to decrease the overall cost and improve the patient experience by minimizing the number of negative breast biopsies. Currently, scintimammography is not commonly used because of MRI; as stated above, however, if additional research and discussion are performed to support its efficacy and use, it could be a valuable asset for the breast imaging world.[7][13][9]
Scintimammography is a diagnostic imaging modality using radiopharmaceuticals to identify breast malignancies. With limited complications, allergic reaction to radiopharmaceutical, and extravasation of radiopharmaceuticals, the most effective way of enhancing healthcare team outcomes is through identifying every step of the process and assigning a role to each team member. Prior to the patient arriving to the hospital or clinic for their examination, the following should be done:
When these roles have been assigned and are accomplished without interruption, the entire healthcare team, as well as the patient, have an overall better experience and outcomes, are more positive. Current Oxford CEBM levels of evidence would be at level 1.
[1] | DeSantis CE,Ma J,Goding Sauer A,Newman LA,Jemal A, Breast cancer statistics, 2017, racial disparity in mortality by state. CA: a cancer journal for clinicians. 2017 Nov; [PubMed PMID: 28972651] |
[2] | Guo F,Kuo YF,Shih YCT,Giordano SH,Berenson AB, Trends in breast cancer mortality by stage at diagnosis among young women in the United States. Cancer. 2018 Sep 1; [PubMed PMID: 30189117] |
[3] | Sondik EJ, Breast cancer trends. Incidence, mortality, and survival. Cancer. 1994 Aug 1; [PubMed PMID: 8039156] |
[4] | Saslow D,Boetes C,Burke W,Harms S,Leach MO,Lehman CD,Morris E,Pisano E,Schnall M,Sener S,Smith RA,Warner E,Yaffe M,Andrews KS,Russell CA, American Cancer Society guidelines for breast screening with MRI as an adjunct to mammography. CA: a cancer journal for clinicians. 2007 Mar-Apr; [PubMed PMID: 17392385] |
[5] | Khalkhali I,Mena I,Diggles L, Review of imaging techniques for the diagnosis of breast cancer: a new role of prone scintimammography using technetium-99m sestamibi. European journal of nuclear medicine. 1994 Apr; [PubMed PMID: 8005161] |
[6] | Scintimammography as an adjunctive breast imaging technology: an evidence-based analysis. Ontario health technology assessment series. 2007; [PubMed PMID: 23074502] |
[7] | Schillaci O,Buscombe JR, Breast scintigraphy today: indications and limitations. European journal of nuclear medicine and molecular imaging. 2004 Jun; [PubMed PMID: 15103505] |
[8] | [Diagnostic accuracy of mammography and mammoscintigraphy in multifocal breast cancer]., Krivorot'ko PV,, Voprosy onkologii, 2013 [PubMed PMID: 23805452] |
[9] | Clinical importance of (99m)Tc-MIBI mammoscintigraphy in multifocal breast lesions., Piwkowski P,Zielińska D,Kołodziejczyk A,Zawisza R,Zebrowski J,Patrzyk R,, Nuclear medicine review. Central & Eastern Europe, 2006 [PubMed PMID: 17304478] |
[10] | [Effectiveness of mammary scintigraphy for determining the results of neoadjuvant polychemotherapy in breast cancer]., Kanaev SV,Krivorot'ko PV,Novikov SN,Semiglazov VF,Semiglzova TIu,Turkevich EA,Zhukova LA,Klimashevskiĭ VF,Ivantsov AO,Donskikh RV,Klimenko VV,Briantseva ZhV,, Voprosy onkologii, 2013 [PubMed PMID: 23909033] |
[11] | Goldsmith SJ,Parsons W,Guiberteau MJ,Stern LH,Lanzkowsky L,Weigert J,Heston TF,Jones E,Buscombe J,Stabin MG, SNM practice guideline for breast scintigraphy with breast-specific gamma-cameras 1.0. Journal of nuclear medicine technology. 2010 Dec; [PubMed PMID: 21057112] |
[12] | van der Pol J,Vöö S,Bucerius J,Mottaghy FM, Consequences of radiopharmaceutical extravasation and therapeutic interventions: a systematic review. European journal of nuclear medicine and molecular imaging. 2017 Jul; [PubMed PMID: 28303300] |
[13] | Novikov SN,Chernaya AV,Krzhivitsky PI,Kanaev SV,Krivorotko PV,Artemyeva AS,Popova NS, {sup}99m{/sup}Tc-MIBI scintimammography and digital mammography in the diagnosis of multicentric breast cancer. Hellenic journal of nuclear medicine. 2019 Sep-Dec; [PubMed PMID: 31587026] |