Holter monitor

Holter monitor
Holter monitor

In medicine, a Holter monitor (often simply Holter) is a type of ambulatory electrocardiography device, a portable device for cardiac monitoring (the monitoring of the electrical activity of the cardiovascular system) for at least 24 to 72 hours (often for two weeks at a time).

The Holter's most common use is for monitoring ECG heart activity (electrocardiography or ECG). Its extended recording period is sometimes useful for observing occasional cardiac arrhythmias which would be difficult to identify in a shorter period. For patients having more transient symptoms, a cardiac event monitor which can be worn for a month or more can be used.[1]

The Holter monitor was developed at the Holter Research Laboratory in Helena Montana by experimental physicists Norman J. Holter and Bill Glasscock,[2][3] who started work on radio telemetry in 1949. Inspired by a suggestion from cardiologist Paul Dudley White in the early 1950s, they redirected their efforts toward development of a wearable cardiac monitoring device.[4] The Holter monitor was released for commercial production in 1962.[4]

When used to study the heart, much like standard electrocardiography, the Holter monitor records electrical signals from the heart via a series of electrodes attached to the chest. Electrodes are placed over bones to minimize artifacts from muscular activity. The number and position of electrodes varies by model, but most Holter monitors employ between three and eight. These electrodes are connected to a small piece of equipment that is attached to the patient's belt or hung around the neck, keeping a log of the heart's electrical activity throughout the recording period. A 12-lead Holter system is also available when precise ECG’s information is required to analyse the exact origin of the abnormal signals.[5]

Data storage

Atrial fibrillation recorded by a Holter monitor

Older devices used reel-to-reel tapes or a standard C90 or C120 audio cassette and ran at a 1.7 mm/s or 2 mm/s speed to record the data. Once a recording was made, it could be played back and analyzed at 60x speed so 24 hours of recording could be analyzed in 24 minutes. More modern units record an EDF-file onto digital flash memory devices. The data is uploaded into a computer which then automatically analyzes the input, counting ECG complexes, calculating summary statistics such as average, minimum and maximum heart rate, and finding candidate areas in the recording worthy of further study by the technician.

Components

Each Holter system consists of two basic parts – the hardware (called monitor or recorder) for recording the signal, and software for review and analysis of the record. Advanced Holter recorders are able to display the signal, which is very useful for checking the signal quality. Very often there is also a “patient button” located on the front side allowing the patient to press it in specific cases such as sickness, going to bed, taking pills, etc.; a special mark will be then placed into the record so that the doctors or technicians can quickly pinpoint these areas when analyzing the signal.

Recorder

The size of the recorder differs depending on the manufacturer of the device. The average dimensions of today's Holter monitors are about 110x70x30 mm but some are only 61x46x20 mm and weigh 99 g.[6] Most of the devices operate with two AA batteries. In case the batteries are depleted, some Holters allow their replacement even during monitoring.

Most of the Holters monitor the ECG via only two or three channels (Note: depending on manufacturer, different counts of leads and lead systems are used). Today's trend is to minimize the number of leads to ensure the patient's comfort during recording. Although two/three channel recording has been used for a long time in the Holter monitoring history, as mentioned above, 12 channel Holters have recently appeared. These systems use the classic Mason-Likar lead system, i.e. producing a signal in the same format as during the common rest ECG and/or stress test measurement. These Holters can occasionally provide information similar to that of an ECG stress test examination. They are also suitable when analyzing patients after myocardial infarction. Recordings from these 12-lead monitors are of a significantly lower resolution than those from a standard 12-lead ECG and in some cases have been shown to provide misleading ST segment representation, even though some devices allow setting the sampling frequency up to 1000 Hz for special-purpose exams such as detection of "late potential".

Another innovation is the inclusion of a triaxial movement sensor, which records the patient's physical activity, and on examination and software processing, extracts three movement statuses: sleeping, standing up, or walking. Some modern devices also have the ability to record a vocal patient diary entry that can be later listened to by the doctor. These data help the cardiologist to better identify events in relation to the patient's activity and diary.

Analyzing software

Screenshot of Holter ECG software

When the recording of ECG signal is finished (usually after 24 hours), it is up to the physician to perform the signal analysis. Since it would be extremely time demanding to browse through such a long signal, there is an integrated automatic analysis process in the software of each Holter device which automatically determines different sorts of heart beats, rhythms, etc. However the success of the automatic analysis is very closely associated with the signal quality. The quality itself mainly depends on the attachment of the electrodes to the patient body. If these are not properly attached, electromagnetic disturbance can influence the ECG signal resulting in a very noisy record. If the patient moves rapidly, the distortion will be even bigger. Such record is then very difficult to process. Besides the attachment and quality of electrodes, there are other factors affecting the signal quality, such as muscle tremors, sampling rate and resolution of the digitized signal (high quality devices offer higher sampling frequency).

The automatic analysis commonly provides the physician with information about heart beat morphology, beat interval measurement, heart rate variability, rhythm overview and patient diary (moments when the patient pressed the patient button). Advanced systems also perform spectral analysis, ischemic burden evaluation, graph of patient's activity or PQ segment analysis. Another requirement is the ability of pacemaker impulses detection and analysis. Such ability may be useful when the physician desires to check for correct basic pacemaker function.

History

The cardiac event monitor has been used for over twenty years. At first, these devices were not portable and had to be used only in hospital buildings. Advances resulted in these devices becoming smaller but were still being used only in hospitals for twenty four to forty eight hours. Soon portable monitors were developed weighing at first thirty pounds, then ten pounds, and one pound. Modern devices are much easier to wear, weighing only a fraction of a pound.

See also

  • BodyKom, a heart monitoring service transmitting data via the mobile cellular telephone network

References

  1. "Holter Monitor". www.heart.org. Retrieved 8 April 2018.
  2. Meldrum, Stuart J (1993). "Obituary for Wilford "Bill" Glasscock". Journal of Ambulatory Monitoring. 6 (3): 243. with the passing of Bill Glasscock, we have lost the second half of one of the most successful partnerships ever to exist in the field of biomedical engineering
  3. "At the Heart of the Invention: The development of the Holter Monitor". National Museum of American History. 2011-11-16. Retrieved 13 August 2016.
  4. 1 2 Hilbel, Thomas; Thomas M Helms; Gerd Mikus; Hugo A Katus; Christian Zugck (10 January 2008). "Telemetry in the clinical setting". Herzschrittmachertherapie & Elektrophysiologie. 19 (3): 146–64. doi:10.1007/s00399-008-0017-2. ISSN 0938-7412. PMID 18956161. Retrieved 4 August 2009.
  5. Herzschrittmacherther Elektrophysiol. 2013 Jun;24(2):92-6. doi: 10.1007/s00399-013-0268-4. Epub 2013 Jun 19. 12-lead Holter electrocardiography. Review of the literature and clinical application update. Su L1, Borov S, Zrenner B.
  6. HeartBug technical specifications Archived 2013-10-04 at the Wayback Machine
This article is issued from Offline. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.