Periodic acid–Schiff stain

Periodic acid–Schiff (PAS) is a staining method used to detect polysaccharides such as glycogen, and mucosubstances such as glycoproteins, glycolipids and mucins in tissues. The reaction of periodic acid oxidizes the vicinal diols in these sugars, usually breaking up the bond between two adjacent carbons not involved in the glycosidic linkage or ring closure in the ring of the monosaccharide units that are parts of the long polysaccharides, and creating a pair of aldehydes at the two free tips of each broken monosaccharide ring. The oxidation condition has to be sufficiently regulated so as to not oxidize the aldehydes further. These aldehydes then react with the Schiff reagent to give a purple-magenta color. A suitable basic stain is often used as a counterstain.

Periodic acid

• PAS diastase stain (PAS-D) is PAS stain used in combination with diastase, an enzyme that breaks down glycogen.

• Alcian blue/periodic acid–Schiff (AB/PAS or AB-PAS) uses alcian blue before the PAS step.

Uses

Gastric signet ring cell carcinoma histopathology, PAS stain
Esophageal candidiasis, PAS stain
Liver in glycogen storage disease, PAS stain

PAS staining is mainly used for staining structures containing a high proportion of carbohydrate macromolecules (glycogen, glycoprotein, proteoglycans), typically found in e.g. connective tissues, mucus, the glycocalyx, and basal laminae.

PAS staining can be used to assist in the diagnosis of several medical conditions:

Presence of glycogen can be confirmed on a section of tissue by using diastase to digest the glycogen from a section, then comparing a diastase digested PAS section with a normal PAS section. The diastase negative slide will show a magenta staining where glycogen is present within a section of tissue. The slide that has been treated with diastase will lack any positive PAS staining in those locations on the slide

PAS staining is also used for staining cellulose. One example would be looking for implanted medical devices composed of nonoxidized cellulose.

If the PAS stain will be performed on tissue, the recommended fixative is 10% neutral-buffered formalin or Bouin solution. For blood smears, the recommended fixative is methanol. Glutaraldehyde is not recommended because free aldehyde groups may be available to react with the Schiff reagent, which may result in false positive staining.[5]

See also

  • Carboxyfluorescein
  • DyLight Fluor, a product line of fluorescent dyes
  • Egyptian blue
  • Eosin
  • Erythrosine
  • Fluorescein
  • Fluorescein amidite (FAM)
  • Fluorescein diacetate hydrolysis, a biochemistry laboratory test
  • Fluorescein isothiocyanate (FITC)
  • Gentian violet
  • Han purple
  • Laser dyes
  • Methyl blue
  • Methyl violet
  • Methylene blue
  • New methylene blue
  • Potassium ferricyanide
  • Potassium ferrocyanide
  • Prussian blue
  • Rose bengal

References

  1. Thomas J. Lawton (27 April 2009). Breast. Cambridge University Press. pp. 55–. ISBN 978-0-521-88159-3. Retrieved 16 November 2010.
  2. (Ladanyi et al 2002 Archived 2003-12-24 at archive.today
  3. C. Hauser (29 August 2005). Mayo Clinic Gastroenterology and Hepatology Board Review. CRC Press. pp. 108–. ISBN 978-0-203-50274-7. Retrieved 16 November 2010.
  4. Khalid, Mohamed (2019). "LABORATORY DIAGNOSIS OF THE CAUSATIVE DERMATOPHYTES OF TINEA CAPITIS" (PDF). World Journal of Pharmaceutical Research. 8 (6): 85–99. doi:10.20959/wjpr20196-14850 (inactive 31 July 2022). Archived from the original (PDF) on 2019-05-03.{{cite journal}}: CS1 maint: DOI inactive as of July 2022 (link)
  5. Carson, Freida L.; Hladik, Christa (2009). Histotechnology: A Self-Instructional Text (3 ed.). Hong Kong: American Society for Clinical Pathology Press. pp. 137–139. ISBN 978-0-89189-581-7.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.