n-BUTYL ACETATE
ICSC: 0399 |
Acetic acid, n-butyl ester Butyl ethanoate C6H12O2 / CH3COO(CH2)3CH3 Molecular mass: 116.2 ICSC # 0399 | CAS # 123-86-4 RTECS # AF7350000 UN # 1123 EC # 607-025-00-1 November 26, 2003 Validated |
TYPES OF HAZARD/ EXPOSURE | ACUTE HAZARDS/ SYMPTOMS | PREVENTION | FIRST AID/ |
FIRE | Flammable. | NO open flames, NO sparks, and NO smoking. | AFFF, alcohol-resistant foam, dry powder, carbon dioxide. |
EXPLOSION | Above 22°C explosive vapour/air mixtures may be formed. | Above 22°C use a closed system, ventilation, and explosion-proof electrical equipment. | In case of fire: keep drums, etc., cool by spraying with water. |
EXPOSURE | |||
INHALATION | Cough. Sore throat. Dizziness. Headache. | Ventilation, local exhaust, or breathing protection. | Fresh air, rest. Refer for medical attention. |
SKIN | Dry skin. | Protective gloves. | Remove contaminated clothes. Rinse skin with plenty of water or shower. |
EYES | Redness. Pain. | Safety goggles, or eye protection in combination with breathing protection. | First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then take to a doctor. |
INGESTION | Nausea. | Do not eat, drink, or smoke during work. | Rinse mouth. Do NOT induce vomiting. Refer for medical attention. |
SPILLAGE DISPOSAL | STORAGE | PACKAGING & LABELLING | ||
Ventilation. Remove all ignition sources. Collect leaking and spilled liquid in sealable metal or glass containers as far as possible. Absorb remaining liquid in sand or inert absorbent and remove to safe place. (Extra personal protection: filter respirator for organic gases and vapours.) | Fireproof. Separated from strong oxidants, strong bases, strong acids. Cool. | Note: 6 R: 10-66-67 S: 2-25 UN Hazard Class: 3 UN Packing Group: II | ||
|
n-BUTYL ACETATE | ICSC: 0399 |
I |
| |||
PHYSICAL |
| |||
ENVIRONMENTAL | The substance is harmful to aquatic organisms. | |||
N O T E S | ||||
|
ADDITIONAL INFORMATION | |||||
|
IMPORTANT LEGAL NOTICE: | Neither NIOSH, the CEC or the IPCS nor any person acting on behalf of NIOSH, the CEC or the IPCS is responsible for the use which might be made of this information. This card contains the collective views of the IPCS Peer Review Committee and may not reflect in all cases all the detailed requirements included in national legislation on the subject. The user should verify compliance of the cards with the relevant legislation in the country of use. The only modifications made to produce the U.S. version is inclusion of the OSHA PELs, NIOSH RELs and NIOSH IDLH values. |
- Page last reviewed: July 22, 2015
- Page last updated: July 1, 2014
- Content source: