Skip directly to search Skip directly to A to Z list Skip directly to navigation Skip directly to page options Skip directly to site content

Cobalt metal dust and fume (as Co)

Synonyms & Trade Names
Cobalt metal dust, Cobalt metal fume
CAS No.
7440-48-4
RTECS No.
GF8750000
DOT ID & Guide
Formula
Co
Conversion
IDLH
20 mg/m3 (as Co)
See: 7440484
Exposure Limits
NIOSH REL
TWA 0.05 mg/m3
OSHA PEL
TWA 0.1 mg/m3 See Appendix G
Measurement Methods
NIOSH 7027 , 7300 , 7301 , 7303 , 9102;
OSHA ID121 , ID125G , ID213
See: NMAM or OSHA Methods
Physical Description
Odorless, silver-gray to black solid.
Molecular Weight
58.9
Boiling Point
5612°F
Melting Point
2719°F
Solubility
Insoluble
Vapor Pressure
0 mmHg (approx)
Ionization Potential
NA
Specific Gravity
8.92
Flash Point
NA
Upper Exposive Limit
NA
Lower Explosive Limit
NA
Noncombustible Solid in bulk form, but finely divided dust will burn at high temperatures.
Incompatibilities & Reactivities
Strong oxidizers, ammonium nitrate
Exposure Routes
inhalation, ingestion, skin and/or eye contact
Symptoms
Cough, dyspnea (breathing difficulty), wheezing, decreased pulmonary function; weight loss; dermatitis; diffuse nodular fibrosis; resp hypersensitivity, asthma
Target Organs
Skin, respiratory system
Personal Protection/Sanitation
(See protection codes)
Skin:Prevent skin contact
Eyes:No recommendation
Wash skin:When contaminated
Remove:When wet or contaminated
Change:Daily
First Aid
(See procedures)
Eye:Irrigate immediately
Skin:Soap wash
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations

NIOSH

Up to 0.25 mg/m3:
(APF = 5) Any quarter-mask respirator.
Click here for information on selection of N, R, or P filters.

Up to 0.5 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.*
(APF = 10) Any supplied-air respirator*

Up to 1.25 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.*

Up to 2.5 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece

Up to 20 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode

Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus

Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus

Important additional information about respirator selection

See also
INTRODUCTION   ICSC CARD: 0782   MEDICAL TESTS: 0055
TOP