Rotenone
Synonyms & Trade Names
1,2,12,12a-Tetrahydro-8,9-dimethoxy-2-(1-methyl-ethenyl)-[1]benzopyrano [3,4-b]furo[2,3-h][1] benzopyran-6(6aH)-oneExposure Limits
NIOSH REL
TWA 5 mg/m3OSHA PEL
TWA 5 mg/m3Physical Description
Colorless to red, odorless, crystalline solid. [insecticide]Molecular Weight
394.4Boiling Point
DecomposesMelting Point
330°FSolubility
InsolubleVapor Pressure
<0.00004 mmHgIonization Potential
?Specific Gravity
1.27Flash Point
?Upper Exposive Limit
?Lower Explosive Limit
?Incompatibilities & Reactivities
Strong oxidizers, alkalisExposure Routes
inhalation, ingestion, skin and/or eye contactSymptoms
irritation eyes, skin, respiratory system; numb mucous membrane; nausea, vomiting, abdominal pain; muscle tremor, incoordination, clonic convulsions, stuporTarget Organs
Eyes, skin, respiratory system, central nervous systemPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:Daily
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Soap wash promptly
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH/OSHA
Up to 50 mg/m3:
(APF = 10) Any air-purifying half-mask respirator with organic vapor cartridge(s) in combination with an N95, R95, or P95 filter. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator
Up to 125 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with an organic vapor cartridge in combination with a high-efficiency particulate filter.
Up to 250 mg/m3:
(APF = 50) Any air-purifying full-facepiece respirator equipped with organic vapor cartridge(s) in combination with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and organic vapor cartridge(s) in combination with a high-efficiency particulate filter
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 2500 mg/m3:
(APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister having an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters./ScbaEsys [potential occupational carcinogen (in the presence of Formaldehyde, Acetaldehyde, or Malonaldehyde)]