p-Terphenyl
Synonyms & Trade Names
1,4-Diphenylbenzene, p-Diphenylbenzene, 4-Phenylbiphenyl, 1,4-Terphenyl, para-Terphenyl, p-TriphenylPhysical Description
White or light-yellow solid.Molecular Weight
230.3Boiling Point
761°FMelting Point
415°FSolubility
InsolubleVapor Pressure
Very lowIonization Potential
7.78Specific Gravity
1.23Flash Point
405°FUpper Exposive Limit
?Lower Explosive Limit
?Incompatibilities & Reactivities
None reportedExposure Routes
inhalation, ingestion, skin and/or eye contactSymptoms
irritation eyes, skin, mucous membrane; thermal skin burns; headache; sore throat; In Animals: liver, kidney damageTarget Organs
Eyes, skin, respiratory system, liver, kidneysPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:Daily
Provide:Eyewash, Quick drench
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Water flush immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH
Up to 25 mg/m3:
(APF = 5) Any quarter-mask respirator.
Click here for information on selection of N, R, or P filters.£
Up to 50 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.£
(APF = 10) Any supplied-air respirator£
Up to 125 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode£
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.£
Up to 250 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 500 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus
See also
INTRODUCTION- Page last reviewed:April 11, 2016
- Page last updated:April 11, 2016
- Content source: