p-Anisidine
Synonyms & Trade Names
para-Aminoanisole, 4-Anisidine, p-MethoxyanilineExposure Limits
NIOSH REL
TWA 0.5 mg/m3 [skin]OSHA PEL
TWA 0.5 mg/m3 [skin]Physical Description
Yellow to brown, crystalline solid with an amine-like odor.Molecular Weight
123.2Boiling Point
475°FMelting Point
135°FSolubility
ModerateVapor Pressure
(77°F): 0.006 mmHgIonization Potential
7.44 eVSpecific Gravity
1.07Flash Point
?Upper Exposive Limit
?Lower Explosive Limit
?Incompatibilities & Reactivities
Strong oxidizersExposure Routes
inhalation, skin absorption, ingestion, skin and/or eye contactSymptoms
headache, dizziness; cyanosis; red blood cell Heinz bodiesTarget Organs
Blood, kidneys, liver, cardiovascular system, central nervous systemPersonal Protection/Sanitation
(See protection codes)Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet or contaminated
Change:Daily
Provide:Quick drench
First Aid
(See procedures)Eye:Irrigate immediately
Skin:Soap wash immediately
Breathing:Respiratory support
Swallow:Medical attention immediately
Respirator Recommendations
NIOSH/OSHA
Up to 5 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100.
Click here for information on selection of N, R, or P filters.
(APF = 10) Any supplied-air respirator
Up to 12.5 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode
(APF = 25) Any powered, air-purifying respirator with a high-efficiency particulate filter.
Up to 25 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 50 mg/m3:
(APF = 1000) Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode*
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter.
Click here for information on selection of N, R, or P filters.
Any appropriate escape-type, self-contained breathing apparatus