Atmospheric Chemistry Suite

The Atmospheric Chemistry Suite (ACS) is a science payload consisting of three infrared spectrometer channels aboard the ExoMars Trace Gas Orbiter (TGO) orbiting Mars since October 2016.[1] The three channels are: the near-infrared channel (NIR), the mid-infrared channel (MIR), and the far infrared channel (FIR, also called TIRVIM).

Atmospheric Chemistry Suite
OperatorEuropean Space Agency
ManufacturerRussia & France
Instrument typeFourier infrared spectrometer
FunctionAtmospheric chemical analysis
Mission duration7 years (planned)
Began operations19 October 2016
Properties
Spectral bandInfrared
Host spacecraft
SpacecraftExoMars Trace Gas Orbiter
OperatorRoscosmos
Launch date14 March 2016, 09:31 (2016-03-14UTC09:31) UTC
RocketProton-M/Briz-M
Launch siteBaikonur 200/39
COSPAR ID2016-017A
OrbitMars

The ACS was proposed in 2011 by Russian Academy Section and eventually accepted by the European Space Agency (ESA) and Roscosmos as one of two Russian instruments onboard TGO.[2] The instrument was funded by Roscosmos and Centre national d'études spatiales (CNES) of France, and has components of both Russia and France. Its development and fabrication was under Russian leadership. The functionality of all the three channels was confirmed during cruise to Mars.

Objectives

The main objective of the ACS suite is to make an inventory and map minor atmospheric species or trace gases in the atmosphere of Mars. This will allow scientists to profile the upper limits on the methane contents, and to possibly to detect sulfur dioxide (SO
2
), a gas of volcanic origin.[2]

Channels

The near-infrared channel (NIR), is a compact spectrometer operating in the range of 0.7–1.7 μm with a resolving power of λ/Δλ ~ 20,000 and with a spectral range of 10–20 nm. It is designed to operate in nadir and in solar occultation modes.[2]

The mid-infrared channel (MIR) is an echelle spectrometer with crossed dispersion, designed exclusively for solar occultation measurements in the 2.2–4.4 μm spectral range with a resolving power of approximately 50,000.[2]

The far-infrared channel covers the thermal infrared spectroscopy; it is a Fourier spectrometer called the TIRVIM. It has an aperture of ~5 cm and it measures the spectrum of 1.7–17 μm. Its main task will be for temperature sounding of the Martian atmosphere in the 15-μm CO
2
band. TIRVIM has 10 times higher performances than the PFS spectrometer of Mars Express orbiter.[2]

Channel designation Abbreviation Wavelength Trace gas detected[2]
Near-Infrared NIR 0.7–1.7 µm H
2
O
, O
2
, CO
2
, O
2
, OH
, and NO
Mid-Infrared MIR 2.2–4.4 µm CH
4
, H
2
O
, HO
2
, HDO, HF, HCl, CO, SO
2
, CO
2
and their isotopes, etc.
Far-Infrared
(Thermal-Infrared)
FIR or TIRVIM 1.7–17 µm Temperature profiles, CO
2
, H
2
O
2
, dust, water ice.

Methane

Of particular interest to this astrobiology mission, is the detection and characterization of the atmospheric methane (CH
4
), as it may be of geological or biological nature. Large differences in the abundances were measured between observations taken in 2003, 2006, and in 2014 NASA reported that the Curiosity rover detected a tenfold increase ('spike') in methane in the atmosphere in late 2013 and early 2014. This suggests that the methane was locally concentrated and is probably seasonal. Because methane on Mars would quickly break down due to ultraviolet radiation from the Sun and chemical reactions with other gases, its persistent presence in the atmosphere also implies the existence of an unknown source to continually replenish the gas.[3]

Measuring the ratio of hydrogen and methane levels on Mars may help determine the likelihood of life on Mars.[4][5] According to the scientists, "...low H2/CH4 ratios (less than approximately 40) indicate that life is likely present and active."[4]

References

  1. Three infrared spectrometers, an atmospheric chemistry suite for the ExoMars 2016 Trace Gas Orbiter. Korablev, O., et al., 2014. J. Appl. Remote Sensing. 8, 4983.
  2. Science Investigations for the Atmospheric Chemistry Suite on ExoMars TGO. (PDF) O. Korablev, N. I. Ignatiev, A. A. Fedorova, A. Yu. Trokhimovskiy, A. V. Grigoriev, A. V. Shakun, Space, F. Montmessin, F. Lefevre, F. Forget. Sixth International Workshop on the Mars Atmosphere: Modelling and Observations. Granada, Spain 17–20 January 2017.
  3. Webster, Christopher R. (23 January 2015). "Mars methane detection and variability at Gale crater" (PDF). Science. 347 (6220): 415–417. Bibcode:2015Sci...347..415W. doi:10.1126/science.1261713. PMID 25515120. S2CID 20304810.
  4. Oze, Christopher; Jones, Camille; Goldsmith, Jonas I.; Rosenbauer, Robert J. (7 June 2012). "Differentiating biotic from abiotic methane genesis in hydrothermally active planetary surfaces". PNAS. 109 (25): 9750–9754. Bibcode:2012PNAS..109.9750O. doi:10.1073/pnas.1205223109. PMC 3382529. PMID 22679287.
  5. Staff (25 June 2012). "Mars Life Could Leave Traces in Red Planet's Air: Study". Space.com. Retrieved 27 June 2012.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.